FIREROD® IMMERSION HEATERS
COMPACT HEATER ENABLES VERSATILE HEATING SYSTEM DESIGN
FIREROD water immersion heaters are ideal for replacing large screw-plug immersion heaters. Because of its compact size the product can be very versatile when designed into a heating system.
These water immersion heaters come complete with a brass 3⁄4 inch National Pipe Thread (NPT) double threaded fitting, which allows you to add conduit boxes. Also, FIREROD immersion heaters are sealed at the lead end with a silicone rubber seal.
Solid copper leads, with silicone rubber sleeves, are provided for unrestricted wiring. These units are recommended for immersion in water or 90+ percent water soluble solutions.
- Nickel-chromium resistance wire precisely centered in the unit ensures even, efficient distribution of heat to the sheath
- MgO insulation compacted to the proper density results in high dielectric strength and contributes to faster heat-up
- Alloy 800 sheath resists corrosion from water
- Metallurgically-bonded conductor pins for trouble-free electrical continuity
- 240 and 480VAC voltage allows flexibility in wiring the heater for use in your particular applications
-
INSULATED TUBE & WIRE THERMOCOUPLES STYLE 62
SERV-RITE® INSULATED TUBE & WIRE THERMOCOUPLES – STYLE 62
STYLE 62 IS FITTED WITH AN ENCAPSULATED MEASURING JUNCTION THAT IS IDEAL FOR CORROSIVE FLUIDS AND GASES, SUCH AS SULFURIC ACID, HYDROFLUORIC ACID, STRONG MINERAL ACIDS AND OILS
-
SERIES CZR
SOLID STATE RELAY OFFERS A COMPACT, VERSATILE MERCURY-FREE SOLUTION
The SERIES CZR solid state relay provides a low-cost, highly-compact and versatile solid state option for controlling electric heat. With DIN-rail and back panel mounting standard on every controller, the CZR solid state relay allows for simple and quick installation.
The extensive capabilities of the SERIES CZR include single-phase, 18 to 42 ampere zero-cross switching up to 600VAC (see output rating curve). It’s unique integrated design removes the guess work associated with selecting a proper heat sink and precise terminations for the application.
This solid state relay controller holds many agency certifications and is ideal for applications that require UL®, CSA and CE approvals. The SERIES CZR is available in VAC/VDC input contactor versions and all configurations are model number dependent and factory selectable.
The SERIES CZR solid state relay is protected by a two-year warranty.
-
Coiled Cable Heaters
Coiled cable heaters are the ultimate design in coiled type heaters. Their design and technical development gives them a longer lifespan than the competition, due to special features including:
-
MINERAL INSULATED THERMOCOUPLES – STYLE AC – STANDARD PLUG OR JACK TERMINATION
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES.
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications
-
LDH SERIES AND D SERIES DUCT HEATERS
EASILY ADAPTED TO MANY NON-PRESSURIZED AIR HEATING SYSTEMS
Watlow duct heaters are constructed of sturdy 0.430 in. (11 mm) diameter WATROD heating elements mounted to a 1⁄4 in. (6 mm) thick steel flange. These air duct heaters are easily adapted to many non-pressurized air-heating systems.
Duct heaters are easily installed in applications requiring a wide range of temperature versus air flow combinations.
The modular duct heater offers increased reliability. The individual modules are removable through the housing of the assembly, which eliminates the need to pull the complete heater from the ductwork. This reduces downtime costs because the heating elements can be replaced individually. Performance improvements include quicker response time and reduced infiltration from the air stream being heated into the electrical enclosure.
Watlow air duct heaters offer advantages over gas or oil fired and open coil electric units with:
-Installation flexibility—no flues or fuel lines
-100 percent energy efficient—no energy loss up the flue
-Universal availability of electricity
-Resistance coil in sheath is protected from corrosive environments
-Duct heaters with general purpose enclosures meet UL® and CSA component recognition to 480 and 600VAC maximum respectively—UL® and CSA file numbers are E52951 and 31388.- Long life alloy 800 sheath resists corrosion/oxidation while protecting resistance coils against contamination
- MgO insulation filled elements compacted to rock hard density maximizes dielectric strength, heat transfer and life
- Field replaceable heating elements permits easy service and reduces downtime
- General purpose terminal enclosure offers easy access to wiring
- WATROD hairpins are recompacted after bending to eliminate hot spots and electrical insulation voids
-
MULTIPOINT THERMOCOUPLES – STYLE AW
ACCURATELY MEASURES TEMPERATURES AT VARIOUS LOCATIONS
Temperature variances exist in all systems, regardless of materials, working fluid or system design. There is not a process that involves heating a particular medium where temperature of that medium is consistent throughout— temperature gradients always exist. Sensing temperature at a single location during a process is acceptable for many applications because temperature gradients are often insignificant. However, there is a need for many applications to monitor temperature in multiple locations to ensure a safe, accurate and cost efficient process. Installing multiple, independent temperature sensors may be impractical due to cost or space limitations.
Multipoint temperature sensors accurately measure temperatures at various locations along the sensor’s length. They are used across a broad range of processes and installations—predominately in applications involving a large or complex process where close temperature control is necessary.
Multipoint temperature sensors are designed to meet requirements of specific applications that include temperature, pressure, chemical environments, time response and number of points required. Sensors are constructed from a variety of protecting tube materials that use XACTPAK mineral insulated, metal-sheathed cable. Multipoint temperature sensors are available in standard or special ASTM thermocouple calibration tolerances. For applications requiring extreme accuracy, special constructions can be made with platinum resistance temperature detectors (RTDs).
-
MINERAL INSULATED THERMOCOUPLES – STYLE AQ – MINIATURE TRANSITIONS
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications.
-
MINERAL INSULATED THERMOCOUPLES – STYLE AC – MINI PLUG OR JACK TERMINATION
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES.
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications.
-
MINERAL INSULATED THERMOCOUPLES – STYLE AR (CONNECTION HEAD) & AT (FOR USE WITH THERMOWELL)
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES.
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications.
-
MINERAL INSULATED THERMOCOUPLES – STYLE AQ – MINIATURE TRANSITIONS
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications.
-
MINERAL INSULATED THERMOCOUPLES – STYLE AF – METAL TRANSITIONS WITH SPRING STRAIN RELIEF
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications.
-
MINERAL INSULATED THERMOCOUPLES – STYLE AC – STANDARD PLUG OR JACK TERMINATION
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES.
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications
-
MINERAL INSULATED THERMOCOUPLES – STYLE AC – MINI PLUG OR JACK TERMINATION
WATLOW’S MINERAL INSULATED (MI) THERMOCOUPLES ARE FAST-RESPONDING, DURABLE AND CAPABLE OF HANDLING HIGH TEMPERATURES.
Manufactured with best-in-class XACTPAK®, Watlow’s trademark for metal sheathed, mineral insulated (MI) thermocouple material, XACTPAK responds fast because the protective metal outer sheath allows use of smaller diameter thermocouple conductors. The rock hard compacted MgO insulation further enhances the sensor’s ability to “read” temperature by transferring heat quickly to the measuring junction.
The XACTPAK protecting sheath and compacted insulation outperform bare wire thermocouples in most applications
-
STAINLESS STEEL SHIM TUBE & WIRE THERMOCOUPLES – STYLE 75
STAINLESS STEEL SHIM TUBE & WIRE THERMOCOUPLES – STYLE 75
THE SHIM STOCK THERMOCOUPLE HAS A LOW PROFILE AND CAN BE PLACED BETWEEN COMPONENTS FOR SURFACE TEMPERATURE MEASUREMENT
-
RING TERMINAL TUBE & WIRE THERMOCOUPLES – STYLE 70
RING TERMINAL TUBE & WIRE THERMOCOUPLES – STYLE 70
THE NICKEL TERMINAL CAN BE PLACED BENEATH EXISTING SCREWS OR BOLTS TO PERMIT SURFACE TEMPERATURE MEASUREMENT
-
RIGID SHEATH THERMOCOUPLES – STYLES 21, 22, 31, 32, 41 & 42
45° OR 90 ° BENDS FOR PLAIN SHEATH, SINGLE SLOT (STANDARD CAP) WITH SPRING, & LARGE DIAMETER SHEATH
The rigid sheath provides protection and accurate placement through bulkheads or platens. Use with a compression fitting for water tight immersion application.
The bent rigid tube offers protection and accurate lead placement around machinery.
-
RIGID SHEATH THERMOCOUPLES – STYLES 20, 23, 24, 25, 30, & 40
PLAIN, STRAIGHT SHEATH – NATIONAL PIPE THREAD (NPT) SS FITTING – FLANGE – SINGLE SLOT (STANDARD CAP) STRAIGHT – LARGE DIAMETER PLAIN, STRAIGHT SHEATH
The rigid sheath provides protection and accurate placement through bulkheads or platens. Use with a compression fitting for water tight immersion application.
Rigid sheath with threaded fitting provides accurate placement in process applications.
The flanged thermocouple allows rapid assembly and low profile when going through bulkheads.