• ECO-HEAT® SYSTEM

    WATLOW’S ECO-HEAT SYSTEM FOR DIESEL GENERATORS UP TO 9L

    Low exhaust gas temperatures (resulting from low load or low ambient conditions) can compromise the performance of your diesel generator’s aftertreatment system and eventually lead to unplanned downtime and expensive repairs. Whether your aftertreatment configuration has a DPF, an SCR or just a DOC, Watlow’s ECO-HEAT system delivers reliable electric heat that can quickly raise the exhaust gas temperature to the correct level.

    Designed to be installed in the exhaust pipe, the ECO-HEAT system places heat directly where it is needed. It uses electricity from your diesel generator to operate when exhaust gas temperatures are too low. Unlike an external load bank that requires additional space and wastes heat to the surrounding environment, the ECO-HEAT system is compact and efficient. You can think of it as a smart internal load bank for your diesel generator. When you place a higher load demand on your generator, the ECO-HEAT system will shut off as the engine exhaust temperature reaches an acceptable threshold.

    • Reduce fuel consumption by over 50 percent as compared to an external load bank
    • Enables passive diesel particulate filter (DPF) to regenerate more effectively
    • Avoid unplanned downtime and expensive service calls
    • Eliminate the need for an external load bank
    • Place exhaust heat exactly where it is needed

  • ENCAPSULATED TUBE & WIRE THERMOCOUPLES

    PERFLUOROALKOXY (PFA) ENCAPSULATED TUBE & WIRE THERMOCOUPLES – STYLE 65

    THE RIGID SHEATH IS COVERED WITH A 0.010 IN. (0.25 MM) WALL OF PFA FOR CORROSION RESISTANCE IN ACID ENVIRONMENTS

    An epoxy seal improves moisture resistance of the sensor and provides a barrier for migrating fumes in corrosive applications.

  • EZ-ZONE® PM LIMIT CONTROLLER

    TAKE THE PAIN OUT OF MEETING YOUR THERMAL LOOP REQUIREMENTS

    The EZ-ZONE PM panel mount limit controllers from Watlow® offer control options to reduce system complexity and the cost of thermal loop ownership. The EZ-ZONE PM limit controller provides high amperage power controller output and over/under limit control in one space saving, panel mount package.

    Because EZ-ZONE PM limit controllers are scalable, the customer only pays for what is needed. This controller is available in 1/32, 1/16, 1/8 and 1/4 DIN panel mount packages.

  • EZ-ZONE® PM LIMIT CONTROLLER

    TAKE THE PAIN OUT OF MEETING YOUR THERMAL LOOP REQUIREMENTS

    The EZ-ZONE PM panel mount limit controllers from Watlow® offer control options to reduce system complexity and the cost of thermal loop ownership. The EZ-ZONE PM limit controller provides high amperage power controller output and over/under limit control in one space saving, panel mount package.

    Because EZ-ZONE PM limit controllers are scalable, the customer only pays for what is needed. This controller is available in 1/32, 1/16, 1/8 and 1/4 DIN panel mount packages.

  • EZ-ZONE® PM PANEL MOUNT CONTROLLER

    HELPS REDUCE SYSTEM COMPLEXITY AND THERMAL LOOP OWNERSHIP COSTS

    The EZ-ZONE PM panel mount controller offers control options that reduce system complexity and thermal loop ownership cost. It can be ordered as a PID controller, an over/under limit controller or its functions can be combined into an integrated controller. An option to integrate a high amperage power controller output with a high-performance PID controller and an over/under limit controller in one space-saving, panel mount package is also available. Many communications options are offered to support connectivity needs.

    Because the EZ-ZONE PM panel mount controller is highly scalable, you pay only for what is needed. This controller is available in 1⁄32,1⁄16,1⁄8 and 1⁄4 DIN panel mount packages. The EZ-ZONE PM controller is easy to use and is ideal for PID controller, over/under limit controller or integrated controller needs.

  • F4T WITH INTUITION®

    F4T WITH INTUITION® INTEGRATED PROCESS CONTROLLER

    THE FLEXIBILITY OF A MODULAR I/O CONTROLLER WITH BEST-IN-CLASS EASE OF USE
    The F4T with INTUITION temperature process controller from Watlow offers a wide range of field removable I/O modules for maximum design flexibility. Configurations can be custom tailored to meet the scaling needs of a tremendous range of equipment and applications while providing exactly the hardware types required for compatibility. The F4T controller also features a 4.3 inch, color, graphical touch panel. Combining power, flexibility and functionality, this new controller offers unmatched versatility, and its best-in-class ease of use could very well make user manuals a thing of the past.

  • FINBAR™ SINGLE- ENDED HEATERS

    DESIGNED TO IMPROVE HEAT TRANSFER TO THE AIR

    Composed of aluminized steel fins press-fitted to a one-inch single-ended FIREBAR element, the FINBAR finned tubular heater is designed to improve heat transfer to the air and permits putting more power in tighter spaces—like forced air ducts, dryers, ovens and load bank resistors.

    Heat transfer, lower sheath temperature and element life are all maximized by the FINBAR heater’s finned construction. Installation is simplified by terminations exiting at one end and mounting accommodations on both ends.

    • Rugged aluminized steel fins increase surface area to improve heat transfer to air
    • Single-ended termination simplifies wiring and installation
    • Stainless steel mounting bracket for ease of installation
    • Lavacone seals provides protection against humid storage conditions – moisture retardant to 221°F (105°C)

  • FIREBAR® SINGLE/DOUBLE-ENDED HEATERS

    FIREBAR heating elements provide added heating performance over standard round tubular heating elements—especially for immersion applications in petroleum-based liquids requiring high kilowatts.

    The FIREBAR’s unique flat surface geometry packs more power in shorter elements and assemblies, along with a host of other performance improvements. These include:

    -Minimizing coking and fluid degrading
    -Enhancing the flow of fluid past the element’s surface to carry heat from the sheath
    -Improving heat transfer with a significantly larger boundary layer allowing much more liquid to flow up and across the sheath’s surface
    FIREBAR elements are available in single- and double-ended constructions with one inch or 5⁄8 inch heights. These two configuration variables make it possible to use FIREBAR elements instead of round tubular elements in virtually all applications.

    FINBAR is a special version of the one inch, single-ended FIREBAR. FINBAR is specially modified with fins to further increase surface area for air and gas heating applications.

    • 70 percent greater surface area per linear inch compared to a 0.430 in. (11 mm) diameter round tubular heater
    • Compacted MgO insulation maximizes thermal conductivity and dielectric strength
    • Precision wound nickel-chromium resistance wires
    • 0.040 in. (1 mm) thick MgO walls transfer heat more efficiently
    • Three resistance coil design readily adapts to a variety of electrical sources and wattages outputs

  • FIREROD® CARTRIDGE HEATERS

    FIREROD CARTRIDGE HEATERS ARE THE PREMIER CHOICE IN SWAGED CARTRIDGE HEATING

    The FIREROD cartridge heater revolutionized the heating element industry in 1954 when it was patented as the first swaged cartridge heater. The mechanical procedure of swaging reduces the diameter of the heater by compacting the unit; this directly improves the heat transfer and efficiency of the heater.

    FIREROD cartridge heaters are built using only the finest materials and construction methods and are backed with extensive quality assurance programs. With premium materials and tight manufacturing controls, the FIREROD heater provides superior heat transfer, uniform temperatures, resistance to oxidation and corrosion and a long life even at high temperatures.

    FIREROD offers many delivery programs to meet your needs.

    • Nickel chromium resistance wire ensures even, efficient distribution of heat to sheath
    • Magnesium oxide insulation of specific grain and purity results in high dielectric strength and faster heat-up
    • Alloy 800 sheath resists oxidation and corrosion from many chemicals, heat and atmospheres
    • Minimal spacing between element wire and sheath results in lower internal temperatures and accommodates design with fewer or smaller heaters
    • UL® and CSA approved flexible stranded wires with lead insulation rated to temperatures of 480°F (250°C)

    PATENTED LEAD ADAPTER (LA) METHOD
    Allows same day shipment on more than 150,000 configurations of stock FIREROD heaters and lead combinations

    INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) 9001 CERTIFIED
    Provides confidence that quality and reliability expectations are met

    CONDUCTOR PINS
    Provides a metallurgical bond to the resistance wire and ensures trouble-free electrical connection


    Material
    Maximum Operating Temperatures
    Maximum Watt Densities
    W/in2
    W/cm2
    Alloy 800 1400 760 400 62
    Stainless Steel 1000 538 400 62
  • FIREROD® IMMERSION HEATERS

    COMPACT HEATER ENABLES VERSATILE HEATING SYSTEM DESIGN

    FIREROD water immersion heaters are ideal for replacing large screw-plug immersion heaters. Because of its compact size the product can be very versatile when designed into a heating system.

    These water immersion heaters come complete with a brass 3⁄4 inch National Pipe Thread (NPT) double threaded fitting, which allows you to add conduit boxes. Also, FIREROD immersion heaters are sealed at the lead end with a silicone rubber seal.

    Solid copper leads, with silicone rubber sleeves, are provided for unrestricted wiring. These units are recommended for immersion in water or 90+ percent water soluble solutions.

    • Nickel-chromium resistance wire precisely centered in the unit ensures even, efficient distribution of heat to the sheath
    • MgO insulation compacted to the proper density results in high dielectric strength and contributes to faster heat-up
    • Alloy 800 sheath resists corrosion from water
    • Metallurgically-bonded conductor pins for trouble-free electrical continuity
    • 240 and 480VAC voltage allows flexibility in wiring the heater for use in your particular applications

  • FLEXIBLE EXTENSIONS TUBE & WIRE THERMOCOUPLES

    FLEXIBLE EXTENSIONS ALLOW THERMOCOUPLES TO BE DISCONNECTED FROM A SYSTEM WITHOUT DISTURBING THE REMAINING WIRING

Main Menu